BBW 46 / DBW 46
2 General Description
201
2. General Description
The water heaters DBW 46 and BBW 46 are used in
combination with the vehicle's own heating system to
heat the vehicle's passenger compartment
defrost the vehicle screens and
preheat water-cooled engines
The water heater operates independent from the vehicle
engine and is connected to the vehicle's cooling system,
electrical system, and fuel system.
The heater designed to the evaporator principle operates
intermittently controlled by the temperature sensor.
Dependent on the coolant temperature the heater
operates in full load with 4.6 kW or in part load with
2.3 kW.
The heaters DBW 46 and BBW 46 basically consist of the
combustion air fan with intake muffler
heat exchanger
burner head with combustion pipe
circulation pump
For control and monitoring the heater includes a
control unit (external)
flame sensor
glow plug
temperature sensor
temperature limiter or temperature fuse
Fuel supply is provided externally by a fuel dosing pump.
9
6
7
8
10
11
1
2
3
1 Fuel connection
2 Flame sensor
3 Glow plug
4 Coolant outlet
5 Temperature limiter
6 Heat exchanger
7 Coolant inlet
8 Temperature sensor
9 Circulation pump
10 Exhaust outlet
11 Combustion air fan
with intake muffler