9 Repair
BBW 46 / DBW 46
904
9.2.2 Replacement of Temperature Limiter
NOTE
The temperature limiter is installed only on heaters from
June 1988 and up or starting from serial number 71771
(BBW 46) and 38177 (DBW 46) or after performing the
modification (see 9.1.2.1).
9.2.2.1 Removal
1. Remove heater (see 8.7.1.1)
2. Break electrical connections (see 9.2.1.1).
WARNING
When removing temperature limiter from installed
condition allow coolant to cool down sufficiently to prevent
skin burns.
Also depressurise cooling system and refit cap
afterwards.
3. Withdraw protective cap (1, Fig. 902).
4. Unscrew temperature limiter (2) from heat exchanger
(9) and remove together with O-ring (3).
5. Perform procedures on components after
disassembly (refer to 9.1.1).
1 Protective cap
2 Temperature limiter
3 O-ring
4 Lock screw
5 O-ring
6 Flame sensor
7 O-ring
8 Temperature sensor
9 Heat exchanger
10 Burner head
11 O-ring
12 Temperature fuse
11
12
1
2
3
8
7
6
5
4
9
10
Fig. 902 Replacement of Temperature Limiter, Temperature Fuse, Temperature Sensor and Flame Sensor