Webasto DBW 46 Wartungshandbuch Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
8 Servicin
g
BBW 46 / DBW 46
802
8.6 Visual Inspections and
Installation Re
g
ulations
8.6.1 Connection to the Vehicle Cooling
System
The installation location of the heater should be as low as
possible to ensure self-venting of the heater and
circulation pump. This applies in particular to the
circulation pump, which is not self-sucking.
The heater is to be connected to the vehicle cooling
system according to Fig. 801 or 802. The amount of
coolant used in the circuit must be at least 4 litres.
The coolant hoses supplied by Webasto must be installed,
other hoses must meet at least the DIN 73411
requirement. The hoses are to be routed upwards and
without kinks to ensure proper venting. Hose connections
must be protected against slippage using hose clamps.
NOTE
The hose clamps are to be torque-tightened with 1.5 Nm
(hose clamps previously used) or with 5 Nm (new, wide
hose clamps).
Old New
After replacing the coolant ensure that the cooling system
is bled thoroughly. The heater and hoses must be
installed so that a static venting is guaranteed.
Insufficient venting may cause malfunctions during
operation by overheating.
Proper venting may be verified by a circulation pump
operating almost noiseless. During operation improper
venting may cause a response of the resettable
temperature limiter or of the temperature fuse.